Motorized Digital Crimp Terminal Pull Tester with USB and LAN WM-831B
The WM-831B is an alternate build of our benchtop motorized pull tester, with the same specification as the WM-831 — peak force to 0.01 N up to 1,000 N, set-speed pull, toothed automatic clamp, force–time curve — plus a LAN port beside the two USB ports on the rear panel for shops that log pull tests to a network. About 11 kg; it sits beside the crimp press. Quoted separately from the WM-831.
Specifications
| Model | WM-831B |
|---|---|
| Measuring range | 0 – 1,000 N (datasheet); 980 N / 100 kgf / 220 lbf (printed manual) — confirm before ordering |
| Resolution | 0.01 N |
| Accuracy | 0.05% (datasheet); ±0.5% FS (printed manual) — confirm before ordering |
| Traction speed | 25 / 50 / 100 mm/min, settable (datasheet); 0 – 300 mm/min (printed manual) |
| Maximum stroke | 48 mm (datasheet); 14 mm (printed manual) — confirm before ordering |
| Clamp | Toothed automatic clamp |
| Interface | USB host, USB device; LAN port on this build |
| Electrical | 20 VDC / 20 VA (datasheet); DC 19 V (printed manual) |
| Dimensions | 404 × 154 × 120 mm (datasheet); 375 × 160 × 130 mm (printed manual) |
| Weight | 10.5 kg (datasheet); 11 kg (printed manual) |
| Electrical configuration | The machine side keeps its rated low-voltage supply. We configure the mains side of the adapter for your site and confirm the input voltage, phase, frequency, current and power cord with plug on the quote. Common site supplies are 120 V, 60 Hz with grounded Type B outlets in the US and Canada, with 208 V or 240 V also found at industrial sites. The UK and Ireland use 230 V, 50 Hz with Type G. Australia and New Zealand use nominal 230 V, 50 Hz with Type I, and some Australian sites list 240 V. Three-phase installations in the UK, Ireland, Australia and New Zealand commonly use 400 V at 50 Hz, with 415 V at some Australian sites. |
| Lead time | Your quote confirms the machine configuration, included accessories and dispatch date. |
| Warranty and support | One-year machine warranty and free remote video support for the life of the equipment. |
| Wear parts | For wear parts, every quote lists them with unit price and the location they ship from. |
| HS Code | 9031.80 (common reference — final classification confirmed by your customs broker) |
| Certification | CE (certificate provided with shipment) |
Key features
- Same tester as the WM-831 with a LAN jack added on the rear panel next to USB host and USB device — for logging pull results to a shop network
- Motorized pull at a set speed, so a pass/fail number means the same thing every shift
- 0.01 N resolution to 1,000 N with a force–time curve and export for the customer record
- Toothed automatic clamp — no jaw adjustment between wire sizes
- Two documents currently give slightly different figures for stroke, accuracy and size; both are printed above and we confirm the shipping unit's figures on the quote
What it processes
- First pull after a new die or applicator is fitted
- Spot-check on crimps beside the press, logged over the network
- Incoming inspection of purchased leads and pigtails
Suited for: a motorized bench pull on crimped terminals up to about 1,000 N, with network logging. For other jobs and machine options: a hand lever — WM-817. A tall column with long stroke — WM-832. USB-only build of this tester — WM-831.
Bring the terminal and the wire. The number that matters is the one on your crimp, and we will pull a sample for you before you order. For a WM-831B quote, tell us what you need to test and which result determines a pass. That helps us check the instrument and fixture together.
Engineering knowledge
Choose and troubleshoot this process
- Crimp Force Monitoring vs Pull Testing, Crimp Height and Cross-SectionBuild a crimp quality plan that combines force monitoring, pull testing, crimp-height measurement and cross-section analysis without confusing their limits.
- How to Choose Wire Harness Testing EquipmentSelect harness testing equipment by test points, two-wire or four-wire resistance measurement, insulation and withstand limits, fixtures and inspection scope.
- Wire Harness Electrical Test Failures: Causes and Corrective ActionsDiagnose open circuits, shorts, high resistance, insulation failures, intermittent contacts, wrong cavity insertion and unstable harness test fixtures.
WM-831B — common questions
How is this different from the WM-831?
Same specification and same tester; this build adds a LAN port on the rear panel. WM-831 is the USB-only version. The two are quoted separately — tell us which page you are looking at.
Why are two numbers on the same row?
Our datasheet and the printed manual for this unit disagree on peak load, accuracy, stroke, speed, voltage, size and weight. We print both rather than pick one, and we confirm the figures of the unit that ships on the quote.
I need a lever gauge, not a motor.
That is the WM-817 — 500 N, hand lever, dial.
I need a vertical column at a set speed.
WM-832 is the 400 mm / 500 N column. Heavy lugs go to the WM-811 or the WM-830.
Is the screen in English?
Export units ship with the English interface and an English manual; tell us your supply voltage and we set the adapter for your country.
Related machines in Testing & Quality Inspection
Motorized Crimp Terminal Pull Tester, 500 N
Model WM-820
Crimp Cross-Section Cutting and Analysis System, 0.01–30 mm²
Model WM-813
Crimp Force Monitoring System, Single or Dual Channel
Model WM-834