🌐 English ▾

Open-Sided Heat Shrink Conveyor Oven with 360 or 560 mm Heating Width WM-696

CE Certified HS Code 8419.89 Heating width 360 or 560 mm Conveyor 0–6 m/min
Get a quote for WM-696 →

Our WM-696 is an open-sided conveyor oven for heating a selected region of long harnesses and assemblies. Configurations provide a 1000 mm heated length with either 360 or 560 mm heating width and a 100 mm opening height. The configuration table separates frame widths, infrared or radiant heating, power and supply ratings. Conveyor speed is 0–6 m/min with a 20 kg load; we confirm the selected build on the quote.

Specifications

ModelWM-696
Machine dimensions (L × W × H)1600 × 700 × 1200 mm; 1600 × 900 × 1200 mm; 1600 × 1200 × 1200 mm; see configuration table
Chamber dimensions (L × W × H)1000 × 400 × 280 mm; 1000 × 600 × 280 mm; see configuration table
Heating space (L × W × H)1000 × 360 × 100 mm; 1000 × 560 × 100 mm; see configuration table
Machine weight100 kg; 110 kg; 120 kg; 130 kg; 150 kg; 140 kg; see configuration table
Conveyor speed0–6 m/min
Power7.2 kW (4.0 kW optional); 8 kW; 10.0 kW; see configuration table
Conveyor load20 kg
Conveyor belt materialHigh-temperature PTFE mesh belt
Heating temperature0–260 °C; 0–300 °C; see configuration table
Heating / temperature controlDouble-sided heating; 2 temperature-control sets
Heating elementsFar-infrared heating tubes; Radiant heating tubes; see configuration table
Hot-air circulation blowerIncluded
Cooling deviceIncluded
Conveyor belt guideIncluded
Power supplyReference configuration: 380 V, 50 Hz (220 V optional); 380 V, 50 Hz; see configuration table
Electrical configurationWe configure the machine’s electrical supply for your installation before shipment. Your quote confirms the voltage, phase, frequency, current and the power cord with plug or industrial connection for your site. Common site supplies are 120 V, 60 Hz with grounded Type B outlets in the US and Canada, with 208 V or 240 V also found at industrial sites. The UK and Ireland use 230 V, 50 Hz with Type G. Australia and New Zealand use nominal 230 V, 50 Hz with Type I, and some Australian sites list 240 V. Three-phase installations in the UK, Ireland, Australia and New Zealand commonly use 400 V at 50 Hz, with 415 V at some Australian sites.
Lead timeYour quote confirms the machine configuration, included accessories and dispatch date.
Warranty and supportOne-year machine warranty and free remote video support for the life of the equipment.
Wear partsFor wear parts, every quote lists them with unit price and the location they ship from.
HS Code8419.89 (common reference — final classification confirmed by your customs broker)
CertificationCE (certificate provided with shipment)

Key features

  • Choose a 1000 mm heating zone with 360 or 560 mm width and 100 mm height for the sleeve region; we confirm clearance and support for the remaining harness and connectors outside the heating zone.
  • Match heating exposure to the sleeve by adjusting conveyor speed over 0–6 m/min and recording the approved setup.
  • Carry work on the heat-resistant PTFE mesh belt with a listed 20 kg load; we confirm the loading pattern with the actual assembly.
  • We set the voltage for your country and ship the English interface and manual.
  • For wear parts, every quote lists them with unit price and the location they ship from.

What it processes

  • Batch heat shrinking of sleeves already positioned on harnesses
  • Heating terminal insulation and cable-joint sleeves in an assembly line
  • Conveyor heating trials for suitable small electrical assemblies

Configuration selection

Choose the heater, working space, frame dimensions and electrical rating together. The selected configuration is confirmed on the quote.

ConfigurationHeating space (L × W × H)Heating temperatureHeating elementsMachine dimensions (L × W × H)Chamber dimensions (L × W × H)Machine weightPowerReference power supplyHeating / temperature controlPhysical temperature controllers (parts list)
360 mm heating width / 700 mm frame / infrared1000 × 360 × 100 mm0–260 °CFar-infrared heating tubes1600 × 700 × 1200 mm1000 × 400 × 280 mm100 kg7.2 kW (4.0 kW optional)380 V, 50 Hz (220 V optional)Double-sided heating; 2 temperature-control sets2
360 mm heating width / 700 mm frame / radiant1000 × 360 × 100 mm0–300 °CRadiant heating tubes1600 × 700 × 1200 mm1000 × 400 × 280 mm110 kg8 kW380 V, 50 HzDouble-sided heating; 2 temperature-control sets2
360 mm heating width / 900 mm frame / infrared1000 × 360 × 100 mm0–260 °CFar-infrared heating tubes1600 × 900 × 1200 mm1000 × 400 × 280 mm110 kg7.2 kW (4.0 kW optional)380 V, 50 Hz (220 V optional)Double-sided heating; 2 temperature-control sets2
360 mm heating width / 900 mm frame / radiant1000 × 360 × 100 mm0–300 °CRadiant heating tubes1600 × 900 × 1200 mm1000 × 400 × 280 mm120 kg8 kW380 V, 50 HzDouble-sided heating; 2 temperature-control sets2
360 mm heating width / 1200 mm frame / infrared1000 × 360 × 100 mm0–260 °CFar-infrared heating tubes1600 × 1200 × 1200 mm1000 × 400 × 280 mm130 kg7.2 kW (4.0 kW optional)380 V, 50 Hz (220 V optional)Double-sided heating; 2 temperature-control sets2
360 mm heating width / 1200 mm frame / radiant1000 × 360 × 100 mm0–300 °CRadiant heating tubes1600 × 1200 × 1200 mm1000 × 400 × 280 mm150 kg8 kW380 V, 50 HzDouble-sided heating; 2 temperature-control sets2
560 mm heating width / 900 mm frame / infrared1000 × 560 × 100 mm0–260 °CFar-infrared heating tubes1600 × 900 × 1200 mm1000 × 600 × 280 mm140 kg10.0 kW380 V, 50 HzDouble-sided heating; 2 temperature-control sets2
560 mm heating width / 1200 mm frame / infrared1000 × 560 × 100 mm0–260 °CFar-infrared heating tubes1600 × 1200 × 1200 mm1000 × 600 × 280 mm150 kg10.0 kW380 V, 50 HzDouble-sided heating; 2 temperature-control sets2

The WM-696 matches a conveyor heating process to prepared sleeved assemblies. Heating space, loading pattern and residence time are selected together so the sleeve can recover while the surrounding assembly is checked.

The configuration table separates the documented builds. Choose the heater arrangement, frame and electrical rating together, then confirm the selected combination on the quote.

For an approval trial, send the complete assembly with the sleeve positioned. We film the heating pass and show the finished recovery before ordering. For a WM-696 quote, share the sleeve size and the approximate dimensions of the part it covers. We'll check which configuration fits your assembly.

Compare configurations before you order Tell us what you need to make. We’ll help you shortlist the equipment and identify which tooling and accessories to include in your quote. Help me choose a machine →

WM-696 — common questions

How do we select the working space?

Use the configuration table for the selected heated space and frame dimensions. We confirm the sleeve position, fixtures and support for the remaining harness and connectors outside the heating zone before ordering.

How do we set temperature and conveyor speed?

We run the actual sleeve on the complete assembly and adjust heating and belt speed to verify sleeve recovery and the surrounding insulation. The approved values and loading arrangement are recorded for the job.

Which configuration should we compare?

Compare WM-693 for the 180 mm heated width and WM-696 for the wider open-sided configurations. Choose the opening and heater arrangement for the complete workpiece.

What is included in the electrical and spare-parts confirmation?

We set the voltage for your country and ship the English interface and manual. For wear parts, every quote lists them with unit price and the location they ship from.

Can we see our own assembly processed?

Send the sleeve material, starting and recovered diameters, sleeve length, complete part dimensions and expected batch volume. We film a trial and show the heated assembly before you confirm the machine.

Related machines in Heat Shrink & Tube Insertion

👋 Need help choosing a machine? Ask me about specifications, processes and sample trials.
Email
Wiro — Equipment Assistant Equipment guidance · quotation team replies within 12 h